enLanguage
Home > Knowledge > Content

Common faults of tractors and troubleshooting methods

May 05, 2023

1. High pressure oil pipe wear leakage

If there is wear and oil leakage at the junction between the convex head at both ends of the tractor's high-pressure oil pipe and the injector and the oil outlet valve, a round copper skin can be cut from the exhaust cylinder gasket, a small hole is pierced in the middle and ground and smoothed, and the pad can be used between the convex pits for emergency.

2. Sudden insufficient fuel supply

If the fuel supply is insufficient during the operation of the tractor, if the air is removed, the plunger is replaced, and the fuel injector is still ineffective, that is, the small steel ball in the ejector needle jack is deflected, so that the fuel injection cannot be atomized. At this time, a small steel ball should be replaced or replaced with a bicycle flywheel steel ball

3. The steering wheel shakes, and the front wheel swings its head

The phenomenon of steering wheel shaking and front wheel shaking is mainly caused by improper positioning of the front wheels and too small tilt angle of the kingpin. In the absence of instrument testing, try to add a plug wedge-shaped iron sheet to the rear end of the leaf spring and the front axle support plane to turn the front axle back, and then increase the caster angle of the kingpin to return to normal after trial operation

4. Automatic gear jump after shifting gear

The automatic gear skipping phenomenon after changing the speed during tractor operation is mainly caused by the wear of the fork shaft groove, the weakening of the fork spring, and the excessive clearance of the connecting rod joint. At this time, the positioning groove should be repaired, the fork spring should be replaced, the gap between the connecting rod joints should be reduced, and the normal speed change can be ensured after the gear is in place.

5. The performance of the oil pump is poor

To solve the problem that the oil pump has poor performance after overhaul or overhaul, and the locomotive cannot start the oil pump for the first time, the oil filter or oil outlet pipe can be removed, and then the oil injector can be filled with oil from the oil outlet hole of the body, and the filter or the oil pipe leading to the oil indicator will be pumped up immediately.

6. Fatigue damage of hydraulic oil pipe

Due to frequent changes in oil pressure and high oil temperature, the pipe wall is frequently opened, which is prone to fatigue damage and accidents.

In order to effectively extend the service life of the hydraulic oil pipe, it is best to use a thin iron wire fired into a spring and put it into the oil pipe for support.

7. Hydraulic brake locomotive brake failure

Carefully check the brake master cylinder and sub-cylinder to see if the brake fluid has been replaced on time and the air from the brake line has been completely removed, and to see if the brake pedal meets the scientific height.

8. Diesel engine oil emits blue smoke

Check whether the cylinder liner piston group is worn, whether the piston ring elasticity is weakened, whether the oil pan oil is added excessively, whether the air filter oil level is too high and other causes, if there is still blue smoke after the solution, attention should be paid to check whether the matching gap between the valve stem and the valve guide is there

Oversize is the underlying cause.

9. Scale causes the engine temperature to be too high

The scale of the engine cooling pump will cause the engine temperature to be too high and accelerate the wear of parts, reduce the power, and burn the oil of the lubricated pump. The elimination method is: select 2 large loofahs to remove the skin and seeds, clean them and put them in the water tank, and replace them regularly to remove scale. The water in the tank should not be changed frequently, and changing the frequency will increase the formation of scale.Wheel Tractor